Yutiq

Fluocinolone Acetonide


Eyepoint Pharmaceuticals, Inc
Human Prescription Drug
NDC 71879-136
Yutiq also known as Fluocinolone Acetonide is a human prescription drug labeled by 'Eyepoint Pharmaceuticals, Inc'. National Drug Code (NDC) number for Yutiq is 71879-136. This drug is available in dosage form of Implant. The names of the active, medicinal ingredients in Yutiq drug includes Fluocinolone Acetonide - .18 mg/1 . The currest status of Yutiq drug is Active.

Drug Information:

Drug NDC: 71879-136
The labeler code and product code segments of the National Drug Code number, separated by a hyphen. Asterisks are no longer used or included within the product code segment to indicate certain configurations of the NDC.
Proprietary Name: Yutiq
Also known as the trade name. It is the name of the product chosen by the labeler.
Product Type: Human Prescription Drug
Indicates the type of product, such as Human Prescription Drug or Human OTC Drug. This data element corresponds to the “Document Type” of the SPL submission for the listing.
Non Proprietary Name: Fluocinolone Acetonide
Also known as the generic name, this is usually the active ingredient(s) of the product.
Labeler Name: Eyepoint Pharmaceuticals, Inc
Name of Company corresponding to the labeler code segment of the ProductNDC.
Dosage Form: Implant
The translation of the DosageForm Code submitted by the firm. There is no standard, but values may include terms like `tablet` or `solution for injection`.The complete list of codes and translations can be found www.fda.gov/edrls under Structured Product Labeling Resources.
Status: Active
FDA does not review and approve unfinished products. Therefore, all products in this file are considered unapproved.
Substance Name:FLUOCINOLONE ACETONIDE - .18 mg/1
This is the active ingredient list. Each ingredient name is the preferred term of the UNII code submitted.
Route Details:INTRAOCULAR
The translation of the Route Code submitted by the firm, indicating route of administration. The complete list of codes and translations can be found at www.fda.gov/edrls under Structured Product Labeling Resources.

Marketing Information:

An openfda section: An annotation with additional product identifiers, such as NUII and UPC, of the drug product, if available.
Marketing Category: NDA
Product types are broken down into several potential Marketing Categories, such as New Drug Application (NDA), Abbreviated New Drug Application (ANDA), BLA, OTC Monograph, or Unapproved Drug. One and only one Marketing Category may be chosen for a product, not all marketing categories are available to all product types. Currently, only final marketed product categories are included. The complete list of codes and translations can be found at www.fda.gov/edrls under Structured Product Labeling Resources.
Marketing Start Date: 12 Oct, 2018
This is the date that the labeler indicates was the start of its marketing of the drug product.
Marketing End Date: 03 Jan, 2026
This is the date the product will no longer be available on the market. If a product is no longer being manufactured, in most cases, the FDA recommends firms use the expiration date of the last lot produced as the EndMarketingDate, to reflect the potential for drug product to remain available after manufacturing has ceased. Products that are the subject of ongoing manufacturing will not ordinarily have any EndMarketingDate. Products with a value in the EndMarketingDate will be removed from the NDC Directory when the EndMarketingDate is reached.
Application Number: NDA210331
This corresponds to the NDA, ANDA, or BLA number reported by the labeler for products which have the corresponding Marketing Category designated. If the designated Marketing Category is OTC Monograph Final or OTC Monograph Not Final, then the Application number will be the CFR citation corresponding to the appropriate Monograph (e.g. “part 341”). For unapproved drugs, this field will be null.
Listing Expiration Date: 31 Dec, 2023
This is the date when the listing record will expire if not updated or certified by the firm.

OpenFDA Information:

An openfda section: An annotation with additional product identifiers, such as NUII and UPC, of the drug product, if available.
Manufacturer Name:EyePoint Pharmaceuticals, Inc
Name of manufacturer or company that makes this drug product, corresponding to the labeler code segment of the NDC.
RxCUI:2099361
2099366
The RxNorm Concept Unique Identifier. RxCUI is a unique number that describes a semantic concept about the drug product, including its ingredients, strength, and dose forms.
Original Packager:Yes
Whether or not the drug has been repackaged for distribution.
NUI:N0000175576
N0000175450
Unique identifier applied to a drug concept within the National Drug File Reference Terminology (NDF-RT).
UNII:0CD5FD6S2M
Unique Ingredient Identifier, which is a non-proprietary, free, unique, unambiguous, non-semantic, alphanumeric identifier based on a substance’s molecular structure and/or descriptive information.
Pharmacologic Class MOA:Corticosteroid Hormone Receptor Agonists [MoA]
Mechanism of action of the drug—molecular, subcellular, or cellular functional activity—of the drug’s established pharmacologic class. Takes the form of the mechanism of action, followed by `[MoA]` (such as `Calcium Channel Antagonists [MoA]` or `Tumor Necrosis Factor Receptor Blocking Activity [MoA]`.
Pharmacologic Class EPC:Corticosteroid [EPC]
Established pharmacologic class associated with an approved indication of an active moiety (generic drug) that the FDA has determined to be scientifically valid and clinically meaningful. Takes the form of the pharmacologic class, followed by `[EPC]` (such as `Thiazide Diuretic [EPC]` or `Tumor Necrosis Factor Blocker [EPC]`.
Pharmacologic Class:Corticosteroid Hormone Receptor Agonists [MoA]
Corticosteroid [EPC]
These are the reported pharmacological class categories corresponding to the SubstanceNames listed above.

Packaging Information:

Package NDCDescriptionMarketing Start DateMarketing End DateSample Available
71879-136-011 POUCH in 1 BOX, UNIT-DOSE (71879-136-01) / 1 APPLICATOR in 1 POUCH / 1 IMPLANT in 1 APPLICATOR12 Oct, 2018N/ANo
Package NDC number, known as the NDC, identifies the labeler, product, and trade package size. The first segment, the labeler code, is assigned by the FDA. Description tells the size and type of packaging in sentence form. Multilevel packages will have the descriptions concatenated together.

Product Elements:

Yutiq fluocinolone acetonide fluocinolone acetonide fluocinolone acetonide polyvinyl alcohol, unspecified water

Indications and Usage:

1. indications and usage yutiq ® (fluocinolone acetonide intravitreal implant) 0.18 mg is indicated for the treatment of chronic non-infectious uveitis affecting the posterior segment of the eye. yutiq contains a corticosteroid and is indicated for the treatment of chronic non-infectious uveitis affecting the posterior segment of the eye. ( 1 )

Warnings and Cautions:

5. warnings and precautions intravitreal injections have been associated with endophthalmitis, eye inflammation, increased intraocular pressure, and retinal detachments. patients should be monitored following the injection. ( 5.1 ) use of corticosteroids may produce posterior subcapsular cataracts, increased intraocular pressure, glaucoma, and may enhance the establishment of secondary ocular infections due to bacteria, fungi, or viruses. ( 5.2 ) the implant may migrate into the anterior chamber if the posterior lens capsule is not intact. ( 5.3 ) 5.1. intravitreal injection-related effects intravitreal injections, including those with yutiq, have been associated with endophthalmitis, eye inflammation, increased or decreased intraocular pressure, and choroidal or retinal detachments. hypotony has been observed within 24 hours of injection and has resolved within 2 weeks. patients should be monitored following the intravitreal injection [see patient counseling information ( 17 )] . 5.2.
steroid-related effects use of corticosteroids including yutiq may produce posterior subcapsular cataracts, increased intraocular pressure and glaucoma. use of corticosteroids may enhance the establishment of secondary ocular infections due to bacteria, fungi, or viruses. corticosteroids are not recommended to be used in patients with a history of ocular herpes simplex because of the potential for reactivation of the viral infection. 5.3. risk of implant migration patients in whom the posterior capsule of the lens is absent or has a tear are at risk of implant migration into the anterior chamber.

Dosage and Administration:

2. dosage and administration for ophthalmic intravitreal injection. ( 2.1 ) the intravitreal injection procedure should be carried out under aseptic conditions. ( 2.2 ) following the intravitreal injection, patients should be monitored for elevation in intraocular pressure and for endophthalmitis. ( 2.2 ) 2.1. general dosing information for ophthalmic intravitreal injection. 2.2. administration the intravitreal injection procedure should be carried out under aseptic conditions, which include use of sterile gloves, a sterile drape, a sterile caliper, and a sterile eyelid speculum (or equivalent). adequate anesthesia and a broad-spectrum microbicide should be given prior to the injection. the injection procedure for yutiq is as follows: just prior to injection, administer topical and/or subconjunctival anesthesia at the injection site (inferotemporal quadrant recommended). administer 2-3 drops of a broad-spectrum microbicide into the lower fornix. the lids may be scrubbed with cotton-tip
ped applicators soaked with a broad-spectrum microbicide. place a sterile lid speculum. have the patient look up and apply additional microbicide solution to the injection site. allow 30-60 seconds for the topical antiseptic to dry prior to injection of yutiq. optimal placement of yutiq is inferior to the optic disc and posterior to the equator of the eye. measure 4 millimeters inferotemporal from the limbus with the aid of callipers for point of entry into the sclera. using sterile procedure, open the sterile foil pouch containing yutiq. remove the yutiq applicator from the sterile pouch by grasping the barrel of the applicator; do not grasp the plunger. remove the black plunger stop from the plunger. carefully remove the protective cap from the needle and inspect the needle tip to ensure it is not bent. remove the trombone wire from the distal end of the needle. prior to injection, keep the applicator tip above the horizontal plane to ensure that the yutiq implant does not fall out of the applicator. gently displace the conjunctiva so that after withdrawing the needle, the conjunctival and scleral needle entry sites will not align. care should be taken to avoid contact between the needle and the lid margin or lashes. insert the needle through the conjunctiva and sclera up to the positive stop of the applicator. depress the plunger at the back of the applicator fully to deliver the yutiq implant into the back of the eye. remove the yutiq applicator from the eye and discard in biohazard sharps container. remove the lid speculum and perform indirect ophthalmoscopy to verify adequate central retinal artery perfusion, absence of any other complications, and to verify the placement of the implant. scleral depression may enhance visualisation of the implant. immediate measurement of intraocular pressure (iop) may be performed at the discretion of the ophthalmologist. following the injection, patients should be monitored for change in intraocular pressure and for endophthalmitis. monitoring may consist of a check for perfusion of the optic nerve head immediately after the injection, tonometry within 30 minutes following the injection, and biomicroscopy between two and seven days following the injection. patients should be instructed to report without delay any symptoms suggestive of endophthalmitis.

Dosage Forms and Strength:

3. dosage forms and strengths yutiq is a non-bioerodible intravitreal implant in a drug delivery system containing 0.18 mg fluocinolone acetonide, designed to release fluocinolone acetonide at an initial rate of 0.25 mcg/day, and lasting 36 months. non-bioerodible intravitreal implant containing 0.18 mg fluocinolone acetonide in a drug delivery system. ( 3 )

Contraindications:

4. contraindications ocular or periocular infections ( 4.1 ) hypersensitivity ( 4.2 ) 4.1. ocular or periocular infections yutiq is contraindicated in patients with active or suspected ocular or periocular infections including most viral disease of the cornea and conjunctiva including active epithelial herpes simplex keratitis (dendritic keratitis), vaccinia, varicella, mycobacterial infections and fungal diseases. 4.2. hypersensitivity yutiq is contraindicated in patients with known hypersensitivity to any components of this product.

Adverse Reactions:

6. adverse reactions in controlled studies, the most common adverse reactions reported were cataract development and increases in intraocular pressure. ( 6.1 ) to report suspected adverse reactions, contact eyepoint pharmaceuticals us, inc. at 1-833-eyepoint (1-833-393-7646) or fda at 1-800-fda-1088 or www.fda.gov/medwatch . 6.1. clinical studies experience because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. adverse reactions associated with ophthalmic steroids including yutiq include cataract formation and subsequent cataract surgery, elevated intraocular pressure, which may be associated with optic nerve damage, visual acuity and field defects, secondary ocular infection from pathogens including herpes simplex, and perforation of the globe where there is thinning of the corne
a or sclera. studies 1 and 2 were multicenter, randomized, sham injection-controlled, masked trials in which patients with non-infectious uveitis affecting the posterior segment of the eye were treated once with either yutiq or sham injection, and then received standard care for the duration of the study. study 3 was a multicenter, randomized, masked trial in which patients with non-infectious uveitis affecting the posterior segment of the eye were all treated once with yutiq, administered by one of two different applicators, and then received standard care for the duration of the study. table 1 summarizes data available from studies 1, 2 and 3 through 12 months for study eyes treated with yutiq (n=226) or sham injection (n=94). the most common ocular (study eye) and non-ocular adverse reactions are shown in table 1 and table 2 . table 1: ocular adverse reactions reported in ≥ 1% of subject eyes and non-ocular adverse reactions reported in ≥ 2% of patients ocular adverse reactions yutiq (n=226 eyes) n (%) sham injection (n=94 eyes) n (%) 1. includes cataract, cataract subcapsular and lenticular opacities in study eyes that were phakic at baseline. 113 of the 226 yutiq study eyes were phakic at baseline; 56 of 94 sham-controlled study eyes were phakic at baseline. cataract 1 63/113 (56%) 13/56 (23%) visual acuity reduced 33 ( 15%) 11 (12%) macular edema 25 ( 11%) 33 (35%) uveitis 22 ( 10%) 33 (35%) conjunctival hemorrhage 17 ( 8%) 5 ( 5%) eye pain 17 ( 8%) 12 (13%) hypotony of eye 16 ( 7%) 1 ( 1%) anterior chamber inflammation 12 ( 5%) 6 ( 6%) dry eye 10 ( 4%) 3 ( 3%) vitreous opacities 9 ( 4%) 8 ( 9%) conjunctivitis 9 ( 4%) 5 ( 5%) posterior capsule opacification 8 ( 4%) 3 ( 3%) ocular hyperemia 8 ( 4%) 7 ( 7%) vitreous haze 7 ( 3%) 4 ( 4%) foreign body sensation in eyes 7 ( 3%) 2 ( 2%) vitritis 6 ( 3%) 8 ( 9%) vitreous floaters 6 ( 3%) 5 ( 5%) eye pruritus 6 ( 3%) 5 ( 5%) conjunctival hyperemia 5 ( 2%) 2 ( 2%) ocular discomfort 5 ( 2%) 1 ( 1%) macular fibrosis 5 ( 2%) 2 ( 2%) glaucoma 4 ( 2%) 1 ( 1%) photopsia 4 ( 2%) 2 ( 2%) vitreous hemorrhage 4 ( 2%) 0 iridocyclitis 3 ( 1%) 7 ( 7%) eye inflammation 3 ( 1%) 2 ( 2%) choroiditis 3 ( 1%) 1 ( 1%) eye irritation 3 ( 1%) 1 ( 1%) visual field defect 3 ( 1%) 0 lacrimation increased 3 ( 1%) 0 non-ocular adverse reactions yutiq (n=214 patients) n (%) sham injection (n=94 patients) n (%) nasopharyngitis 10 ( 5%) 5 ( 5%) hypertension 6 ( 3%) 1 ( 1%) arthralgia 5 ( 2%) 1 ( 1%) table 2: summary of elevated iop related adverse reactions adverse reactions yutiq (n=226 eyes) n (%) sham (n=94 eyes) n (%) iop elevation ≥ 10 mmhg from baseline 50 (22%) 11 (12%) iop elevation > 30 mmhg 28 (12%) 3 (3%) any iop-lowering medication 98 (43%) 39 (41%) any surgical intervention for elevated iop 5 (2%) 2 (2%) figure 1: mean iop during the studies figure 1

Adverse Reactions Table:

Table 1: Ocular Adverse Reactions Reported in ≥ 1% of Subject Eyes and Non-Ocular Adverse Reactions Reported in ≥ 2% of Patients
Ocular
ADVERSE REACTIONSYUTIQ (N=226 Eyes) n (%)Sham Injection (N=94 Eyes) n (%)
1. Includes cataract, cataract subcapsular and lenticular opacities in study eyes that were phakic at baseline. 113 of the 226 YUTIQ study eyes were phakic at baseline; 56 of 94 sham-controlled study eyes were phakic at baseline.
Cataract163/113 (56%)13/56 (23%)
Visual Acuity Reduced33 ( 15%)11 (12%)
Macular Edema25 ( 11%)33 (35%)
Uveitis22 ( 10%)33 (35%)
Conjunctival Hemorrhage17 ( 8%)5 ( 5%)
Eye Pain17 ( 8%)12 (13%)
Hypotony Of Eye16 ( 7%)1 ( 1%)
Anterior Chamber Inflammation12 ( 5%)6 ( 6%)
Dry Eye10 ( 4%)3 ( 3%)
Vitreous Opacities9 ( 4%)8 ( 9%)
Conjunctivitis9 ( 4%)5 ( 5%)
Posterior Capsule Opacification8 ( 4%)3 ( 3%)
Ocular Hyperemia8 ( 4%)7 ( 7%)
Vitreous Haze7 ( 3%)4 ( 4%)
Foreign Body Sensation In Eyes7 ( 3%)2 ( 2%)
Vitritis6 ( 3%)8 ( 9%)
Vitreous Floaters6 ( 3%)5 ( 5%)
Eye Pruritus6 ( 3%)5 ( 5%)
Conjunctival Hyperemia5 ( 2%)2 ( 2%)
Ocular Discomfort5 ( 2%)1 ( 1%)
Macular Fibrosis5 ( 2%)2 ( 2%)
Glaucoma4 ( 2%)1 ( 1%)
Photopsia4 ( 2%)2 ( 2%)
Vitreous Hemorrhage4 ( 2%)0
Iridocyclitis3 ( 1%)7 ( 7%)
Eye Inflammation3 ( 1%)2 ( 2%)
Choroiditis3 ( 1%)1 ( 1%)
Eye Irritation3 ( 1%)1 ( 1%)
Visual Field Defect3 ( 1%)0
Lacrimation Increased3 ( 1%)0
Non-ocular
ADVERSE REACTIONSYUTIQ (N=214 Patients) n (%)Sham Injection (N=94 Patients) n (%)
Nasopharyngitis10 ( 5%)5 ( 5%)
Hypertension6 ( 3%)1 ( 1%)
Arthralgia5 ( 2%)1 ( 1%)

Table 2: Summary of Elevated IOP Related Adverse Reactions
ADVERSE REACTIONSYUTIQ (N=226 Eyes) n (%)Sham (N=94 Eyes) n (%)
IOP elevation ≥ 10 mmHg from Baseline50 (22%)11 (12%)
IOP elevation > 30 mmHg28 (12%)3 (3%)
Any IOP-lowering medication98 (43%)39 (41%)
Any surgical intervention for elevated IOP5 (2%)2 (2%)

Use in Specific Population:

8. use in specific populations 8.1 pregnancy risk summary adequate and well-controlled studies with yutiq have not been conducted in pregnant women to inform drug associated risk. animal reproduction studies have not been conducted with yutiq. it is not known whether yutiq can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity. corticosteroids have been shown to be teratogenic in laboratory animals when administered systemically at relatively low dosage levels. yutiq should be given to a pregnant woman only if the potential benefit justifies the potential risk to the fetus. all pregnancies have a risk of birth defect, loss, or other adverse outcomes. in the united states general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2% to 4% and 15% to 20%, respectively. 8.2 lactation risk summary systemically administered corticosteroids are present in human milk and can suppress
growth, interfere with endogenous corticosteroid production. clinical or nonclinical lactation studies have not been conducted with yutiq. it is not known whether intravitreal treatment with yutiq could result in sufficient systemic absorption to produce detectable quantities of fluocinolone acetonide in human milk, or affect breastfed infants or milk production. the developmental and health benefits of breastfeeding should be considered, along with the mother's clinical need for yutiq and any potential adverse effects on the breastfed child from yutiq. 8.4 pediatric use safety and effectiveness of yutiq in pediatric patients have not been established. 8.5 geriatric use no overall differences in safety or effectiveness have been observed between elderly and younger patients.

Use in Pregnancy:

8.1 pregnancy risk summary adequate and well-controlled studies with yutiq have not been conducted in pregnant women to inform drug associated risk. animal reproduction studies have not been conducted with yutiq. it is not known whether yutiq can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity. corticosteroids have been shown to be teratogenic in laboratory animals when administered systemically at relatively low dosage levels. yutiq should be given to a pregnant woman only if the potential benefit justifies the potential risk to the fetus. all pregnancies have a risk of birth defect, loss, or other adverse outcomes. in the united states general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2% to 4% and 15% to 20%, respectively.

Pediatric Use:

8.4 pediatric use safety and effectiveness of yutiq in pediatric patients have not been established.

Geriatric Use:

8.5 geriatric use no overall differences in safety or effectiveness have been observed between elderly and younger patients.

Description:

11. description yutiq is a sterile non-bioerodible intravitreal implant containing 0.18 mg fluocinolone acetonide in a 36-month sustained-release drug delivery system. yutiq is designed to release fluocinolone acetonide at an initial rate of 0.25 mcg/day. yutiq is preloaded into a single-dose applicator to facilitate injection of the implant directly into the vitreous. the drug substance is a synthetic corticosteroid, fluocinolone acetonide. the chemical name for fluocinolone acetonide is (6α,11β, 16α)-6,9-difluoro-11,21-dihydroxy-16,17-[(1-methylethylidene)bis-(oxy)]-pregna-1,4-diene-3,20-dione. its chemical structure is: mw 452.50; molecular formula c 24 h 30 f 2 0 6 fluocinolone acetonide is a white or almost white, microcrystalline powder, practically insoluble in water, soluble in methanol, ethanol, chloroform and acetone, and sparingly soluble in ether. each yutiq consists of a light brown 3.5mm x 0.37mm implant containing 0.18 mg of the active ingredient fluocinolone acetonide and the following inactive ingredients: polyimide tube, polyvinyl alcohol, silicone adhesive and water for injection. chemical structure

Clinical Pharmacology:

12. clinical pharmacology 12.1 mechanism of action corticosteroids inhibit inflammatory responses to a variety of inciting agents including multiple inflammatory cytokines. they inhibit edema, fibrin deposition, capillary dilation, leukocyte migration, capillary proliferation, fibroblast proliferation, deposition of collagen, and scar formation associated with inflammation. corticosteroids are thought to act by inhibition of phospholipase a 2 via induction of inhibitory proteins collectively called lipocortins. it is postulated that these proteins control biosynthesis of potent mediators of inflammation such as prostaglandins and leukotrienes by inhibiting release of the common precursor, arachidonic acid. arachidonic acid is released from membrane phospholipids by phospholipase a 2 .

Mechanism of Action:

12.1 mechanism of action corticosteroids inhibit inflammatory responses to a variety of inciting agents including multiple inflammatory cytokines. they inhibit edema, fibrin deposition, capillary dilation, leukocyte migration, capillary proliferation, fibroblast proliferation, deposition of collagen, and scar formation associated with inflammation. corticosteroids are thought to act by inhibition of phospholipase a 2 via induction of inhibitory proteins collectively called lipocortins. it is postulated that these proteins control biosynthesis of potent mediators of inflammation such as prostaglandins and leukotrienes by inhibiting release of the common precursor, arachidonic acid. arachidonic acid is released from membrane phospholipids by phospholipase a 2 .

Nonclinical Toxicology:

13. nonclinical toxicology 13.1 carcinogenesis, mutagenesis, impairment of fertility long-term animal studies have not been conducted to determine the carcinogenic potential or the effect on fertility of yutiq. fluocinolone acetonide was not genotoxic in vitro in the ames test (s. typhimurium and e. coli) and the mouse lymphoma tk assay, or in vivo in the mouse bone marrow micronucleus assay.

Carcinogenesis and Mutagenesis and Impairment of Fertility:

13.1 carcinogenesis, mutagenesis, impairment of fertility long-term animal studies have not been conducted to determine the carcinogenic potential or the effect on fertility of yutiq. fluocinolone acetonide was not genotoxic in vitro in the ames test (s. typhimurium and e. coli) and the mouse lymphoma tk assay, or in vivo in the mouse bone marrow micronucleus assay.

Clinical Studies:

14. clinical studies the efficacy of yutiq was assessed in two randomized (2:1, yutiq: sham-injection), multi-centre, double-masked, parallel-groups studies (nct #01694186 and #02746991) that enrolled patients with non-infectious uveitis affecting the posterior segment of the eye. the primary efficacy endpoint in both trials was the proportion of patients who experienced a recurrence of uveitis in the study eye within 6 months of follow-up; recurrence was also assessed at 12 months. recurrence of uveitis was defined as either deterioration in visual acuity, vitreous haze attributable to non-infectious uveitis or the need for rescue medications. table 3: efficacy results of recurrence of uveitis in randomized study eyes study 1 study 2 yutiq n = 87 sham n = 42 yutiq n = 101 sham n = 52 eyes with recurrence within 6 months, n (%) 16 (18%) 33 (79%) 22 (22%) 28 (54%) difference (95% ci) in recurrence rates 60% (41%, 73%) 32% (15%, 48%) p-value < 0.01 < 0.01 eyes with recurrence within 12 m
onths, n (%) 24 (28%) 36 (86%) 33 (33%) 31 (60%) difference (95% ci) in recurrence rates 58% (40%, 70%) 27% (9%, 43%) figure 2: time to first recurrence of uveitis (itt: all randomized patients) figure 2

How Supplied:

16. how supplied/storage and handling yutiq ® (fluocinolone acetonide intravitreal implant) 0.18 mg is supplied in a sterile single-dose preloaded applicator with a 25-gauge needle, packaged in a sealed sterile foil pouch inside a sealed tyvek pouch inside a carton box. ndc 71879-136-01 storage: store at 15° c to 30° c (59° f to 86° f).

Information for Patients:

17. patient counseling information steroid-related effects advise patients that a cataract may occur after treatment with yutiq. if this occurs, advise patients that their vision will decrease, and they will need an operation to remove the cataract and restore their vision. advise patients that they may develop increased intraocular pressure with yutiq treatment, and the increased iop may need to be managed with eye drops or surgery. intravitreal injection-related effects advise patients that in the days following intravitreal injection of yutiq, they are at risk for potential complications including, but not limited to, the development of endophthalmitis or changes in intraocular pressure. when to seek physician advice advise patients that if the eye becomes red, sensitive to light, painful, or develops a change in vision, they should seek immediate care from an ophthalmologist. driving and using machines inform patients that they may experience temporary visual blurring after receivi
ng an intravitreal injection. advise patients not to drive or use machines until this has been resolved. manufactured by: eyepoint pharmaceuticals us, inc. 480 pleasant street watertown, ma 02472 usa patented. see https://eyepointpharma.com/patent-notification/

Package Label Principal Display Panel:

Principal display panel - kit carton ndc 71879-136-01 0.18 mg yutiq™ (fluocinolone acetonide intravitreal implant) 0.18 mg contains: one sterile intravitreal implant in a single dose only applicator with 25 gauge needle. each implant contains: active: 0.18 mg fluocinolone acetonide inactive: polyimide tube, polyvinyl alcohol, silicone adhesive and water for injection. do not use if inner pouch is damaged. dispose of the applicator safely in biohazard sharps container. rx only. store at 15° c to 30° c (59° f to 86° f). keep out of reach of children. principal display panel - kit carton


Comments/ Reviews:

* Data of this site is collected from www.fda.gov. This page is for informational purposes only. Always consult your physician with any questions you may have regarding a medical condition.